THE SINGLE BEST STRATEGY TO USE FOR DP50RB

The Single Best Strategy To Use For Dp50rb

The Single Best Strategy To Use For Dp50rb

Blog Article

one.two.2 Warning Labels Warning Labels Meaning Remember to very carefully look at this guide prior to use machine. The following labels undoubtedly are a. Usually do not location the product on a sloped area. In any other case the accessible if the program unit might slide, causing private injury or maybe the unit functions Using the mobile malfunction.

The DP-50 Pro is an progressive, high-functionality Ultrasound Process engineered to assist you to have the insights you require. The Process’s strong engine and superior-pace processing supply exceptional graphic high-quality and a whole info management Alternative.

Click Concur and Progress to just accept cookies and go directly to the site or click on More Information to determine specific descriptions of the categories of cookies and pick out irrespective of whether to simply accept selected cookies even though on the location.

Permits usage of multiple scanned angles to type one graphic, resulting in enhanced contrast resolution and enhanced visualization

Site one hundred forty five Clear control panel Applications: dry tender cloth, mild soapy h2o  System:  Use dry comfortable cloth to scrub the surface area of the process. If your technique is dirty, moisten the tender cloth with mild soapy water and wipe off any stains. Use dry comfortable fabric to eliminate any moisture and permit all challenging surfaces to fully air-dry. Web page 146: Clean The Peripherals

Do not use any cables besides the cables presented With all the machine by Mindray. 3. Use the cable furnished with This method to attach the printer. Other cables may possibly bring about electric powered shock. Site fifteen: Mechanical Safety

General performance Test five.five.1 Examination System Resolution Detection depth Geometric Place Precision Blackout area test Report the exam pictures five.five.two Test Material The picture used Here's only for reference, stick with the picture outcome in the real NOTE: circumstance. Prerequisites: Display: established the distinction and brightness for the clinical software value (or even the default position) Procedure surroundings: dark room, simulating the medical application ecosystem. Web page 76 In condition the transverse resolution tests targets are horizontally exhibited, record the minimum length of two targets which might be Obviously regarded. Repeat the operation higher than for that transverse resolution testing targets at other depths. As demonstrated in determine beneath. Axial resolution ... Web site seventy seven When utilizing the convex probe, retain the transverse resolution tests targets to notice: be shown near the midline. When using a linear probe with steer perform, usually do not turn on the steer perform when perform the transverse resolution exam. Zoom inside the area where by the targets Found if essential. The diameter with the concentrate on point at a specific depth is equal to your transverse resolution in the depth. Web page seventy eight five.

5.2.three Geometric positioning accuracy Longitudinal geometric positioning precision  Examination Stage: Do adjustments as the way in which in testing the most depth. History the gap by 20mm Just about every section within the longitudinal targets line using the measurement caliper; Pick the value with the best error (to 20mm), work out the precision using the components below The measurement caliper really should be positioned on the upper edge of the concentrate on, Be aware:... Web page seventy nine Transverse geometric positioning precision  Test Action: Include the scan surface area of the phantom with water or few gel, Carefully contact the probe With all the scan area Alter the depth, creating the transverse targets to generally be exhibited during the picture. Modify the main focus point being posited beside the transverse targets (the standard is not really very clear) Alter parameters like achieve, TGC, generating Each individual transverse targets to generally be Evidently exhibited. Page eighty five.5.two.4 Blackout Region Exam Stage: Address the scan floor in the phantom with water Dp50rb login or few gel, gently Speak to the probe With all the scan surface Regulate the depth at a reduced worth, and established the main target at the nearest destination to the scan area. Decrease the worth of parameters like AP, Get until eventually the history sound just could be noticed. Page eighty one: Software Improve And Servicing

Be aware: Prior to uploading the log, be certain the ultrasound method has actually been connected to community, or else, the procedure could alert “couldn't hook up with server” The server (smtp.

Assist 4D probe; figure out the probe via the ID code; switch the 4D travel sign via the  electrical relay to generate the 4D probe get the job done normally. four.2.2 Primary board The principle board could be divided into two parts: entrance-stop of the key board and again-conclude of the key board.

Return to your system preset interface. The option position changes into Uninstalled. The uninstalling operate is distinctive to inner people.

This handbook could referring to information and facts safeguarded by copyright or patents and would not Express any license underneath the patent legal rights or copyright of Mindray, or of Other individuals. Site nine: Assertion

Cut off cable ties connecting the key device over the display by diagonal slicing pliers, and afterwards pull out the corresponding cable plugs.

Your Device for further biopsy: making it possible for adjustments to the scan line to get far better visibility with the needle, nerves and small vessels, guaranteeing the continuity of all facts.